In this work we studied the behavior of the photovoltaic panels in a uniform and non uniform illumination conditions on the module surface. For this a group of UDTS50 PV panels was modeled and simulated under Matlab/Simulink environment toward discuss and compare the external characteristics in the two studied situations. The simulation results obtained shows well the effect of the shadow in a photovoltaic installation, which requires particular precautions in order to guarantee the maximum power possible under all operation conditions.
Photovoltaic panels, PV, external characteristic, Global Maximum Power Point Tracking (GMPPT), Local Maximum Power Point Tracking (GMPPT), Uniform and nonuniform illumination conditions.