Rеvuе des Energies Renouvelables
Volume 12, Numéro 1, Pages 69-75
2009-03-31

Characterisation Of Platinum Electrode Modified With Phosphate Rock For Cd2+ Ions Detection

Authors : Hamel A. . Morakchi K. . Guerfi K. . Louhi A. . Kherrat R. .

Abstract

In the present paper we report the characterization of platinum electrode modified with a polymeric membrane. The use of natural minerals such as phosphate rock (PR) from the mine of Djebel Onk (Algeria) was investigated as ionophore for Cd2+ ions detection. The impedance data were adjusted from 100 mHz to 100 kHz and at polarisation - 200 mV. The maximum exchange was obtained between pH 4 and 6. Low detection limit is about 10-5 M.

Keywords

Electrochemical sensors, Phosphate rock, Impedance spectroscopy, Ion exchange.

Application Of Central Composite Design And Response Surface Methodology For Optimization Of Lead Ions Sorption On Hydroxyapatite Recovered From The Natural Phosphate Of Djbel Onk-tebessa

Ziani Salima .  Ait Ali Salima .  Brahmi Aghilas .  Lakehal Yanis Zakaria .  Meski Samira .  Khireddine Hafit . 
pages 1-7.


Contribution à L’étude De L’immobilisation Des Ions Plomb En Solution Aqueuse Par L’adsorption Sur Le Phosphate Naturel

Naima Filali .  Mazouz Radia .  Hamel Abdallah .  Hattab Zhour .  Guerfi Kamel . 
pages 88-89.


Study Of Ions Exchanges During The Adsorption Of La3+ Ions Onto Montmorillonite K10

Zeoual Somia .  Kebabi Brahim .  Bougherara Hassina . 
pages 44-49.